The Rheem and Ruud names are synonymous with quality and customer service and allows Rheem Parts and our partners to capitalize on this brand recognition with professional plumbers. BusinessPartner Rheem is a proven business partner to our customers. Sales Professionals Rheem Water Heating has an exceptional network of sales professionals. Rheem 42VP50FW Power Vent Natural Gas Water Heater, 50 Gallon - Water Heater Parts - Amazon.com.

Advertising

10018

®

SYSTEM SENTINEL

POWER

THERMOSTAT

IGNITION

PILOT VALVE

MAIN VALVE

ECO

“System Sentinel” Diagnostic System

The “System Sentinel” Diagnostic system on this water heater provides the user or service technician with a visual representation of the
operational status of the various sections of the water heater’s control system. A quick glance at the System Sentinel panel on the front of
the heater will give an indication of where to begin trouble shooting of a non operational heater.

The LED’s (light emitting diodes) on the panel are arranged from top to bottom based on their function in the normal sequence of operation,
and their function is explained as follows:

POWER

When illuminated, this green LED indicates that 120VAC power is

being supplied to the heater, the ON/OFF switch is functioning and

the 24V transformer is functioning properly.
(Refer to Section 1 of Troubleshooting Guide)

THERMOSTAT

When illuminated, this red LED indicates that the ther-

mostat is functioning(calling for heat) and 24VAC power

is being supplied to the relay (to turn on the blower) and

the N/C terminal of the pressure switch with N/C and N/O

terminals.
(Refer to Section 2 of Troubleshooting Guide)

IGNITION

When illuminated, this red LED indicates that 24 VAC

power is being supplied to the Ignition Control Module,

and the ignition sequence has begun. The N/O side of the

pressure switch with N/C and N/O terminals closes

Vent

(Refer to Section 3 of Troubleshooting Guide)

PILOT VALVE

When illuminated, this red LED indicates that the Ignition

Control Module is supplying 24 VAC power to the ECO

(Energy Cut Off device), or High Limit.
(Refer to Section 4 of Troubleshooting Guide)

ECO

When illuminated, this red LED indicates that the ECO

Power Vent Gas Water Heater

(Energy Cut Off device), or High Limit is closed, and 24

VAC power is being supplied to the PV (Pilot Valve) ter-

Rheem power vent water heater 42vp50fw manual price

minal on the Gas Control Valve.
(Refer to Section 5 of Troubleshooting Guide)

MAIN VALVE

When illuminated, this red LED indicates that the Ignition Control

Module is supplying 24 VAC power to the MV (Main Valve) terminal

on the Gas Control Valve.
(Refer to Section 6 of Troubleshooting Guide)